List of parameters
Parameter
1-647
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
1020: T = 20 * r20003
1024: T = 24 * r20003
1032: T = 32 * r20003
1040: T = 40 * r20003
1048: T = 48 * r20003
1064: T = 64 * r20003
1080: T = 80 * r20003
1096: T = 96 * r20003
9003: Before setp chann
Index:
[0] = Run-time group 0
[1] = Run-time group 1
[2] = Run-time group 2
[3] = Run-time group 3
[4] = Run-time group 4
[5] = Run-time group 5
[6] = Run-time group 6
[7] = Run-time group 7
[8] = Run-time group 8
[9] = Run-time group 9
Dependency:
Refer to: r20008
Caution:
The assignment of the properties of the run-time groups should not be changed on drives in operation as this could
result in discontinuous signal transitions depending on the blocks used. At the 1st arithmetic cycle after the change,
the respective internal initialization value is present at the block connections and in each subsequent cycle the cal-
culated value is then present.
Note:
Re value = 1 ... 256:
This value can only be set if, for sampling time T_sample of this run-time group, the following applies: 1 ms <=
T_sample <= r20003.
If value = 9003:
The fixed run-time groups p20000[x] = 9003 log on with the sampling time of the setpoint channel, although the
sampling time must be at least 1 ms. If, as a result of this limit, the actual sampling time deviates from the sampling
time of the setpoint channel p0115[3], alarm A20103 is output. Another run-time group with a sampling time >= 1
ms should be selected. "Calculate before setpoint channel" means before function diagrams 3010, 3020, 3030,
3040, etc. are calculated, if the setpoint channel is activated (p0108.8 = 1). If, e.g. for SERVO, a setpoint channel
has not been configured (p0108.8 = 0), then the calculation is made before function diagram 3095.
Description:
Displays the current sampling time of the run-time group 0 to 9.
Index:
[0] = Run-time group 0
[1] = Run-time group 1
[2] = Run-time group 2
[3] = Run-time group 3
[4] = Run-time group 4
[5] = Run-time group 5
[6] = Run-time group 6
[7] = Run-time group 7
[8] = Run-time group 8
[9] = Run-time group 9
r20001[0...9]
Run-time group sampling time / RTG sampling time
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]