F
u
nct
ion
d
ia
gr
am
s
Diagn
ostics
2-
94
6
© Siemens AG
2012 All Rights Reserved
SINAMICS
S110
List Manual (LH7
), 06/201
2, 6SL3097-
4AP
1
0-0BP3
Fi
g.
2
-1
74
806
5 – Al
arm
b
uffer
- 8065 -
Function diagram
8
7
6
5
4
3
2
1
fp_8065_98_eng.vsd
DO: All objects
SINAMICS S110
29.06.10 V04.04.00
Diagnostics - Alarm buffer
Alarm value
Alarm time
"come"
Alarm time
"removed"
Alarm code
RESET
Alarm comes
Alarms
counter
p2111
p2111 = 0:
Alarm buffer is deleted
1
Delete alarm buffer
r2122 = 0
r2123 = 0
r2124 = 0
r2125 = 0
r2134 = 0
r2145 = 0
r2146 = 0
Alarm goes
Alarm comes
1
Alarm buffer change
r2121
Counter
16 bit
III
RESET
III
RESET
Fault buffer change [8060.8]
Sum, buffer changed
r2120
III
RESET
1
Fault/alarm buffer changes from
other drive objects
POWER ON
16 bit counter,
free running
16 bit counter,
free running
Alarm number
r2110
Operating time
Alarm times
Alarm buffer
change
POWER ON
r2132
Actual alarm code
0 = "No alarm present"
External alarm 1
r2138.10
External alarm 2
r2138.11
External alarm 3
r2138.12
[2548.2]
Background
Refer to [1020.7]
[2546.3]
p2112
[2546.3]
p2116
[2546.3]
p2117
r2122[0]
r2122[1]
r2122[7]
r2124[0] [I32]
r2134[0] [Float]
r2124[1] [I32]
r2134[1] [Float]
r2124[7] [I32]
r2134[7] [Float]
r2123[0] [ms]
r2145[0] [d]
r2123[1] [ms]
r2145[1] [d]
r2123[7] [ms]
r2145[7] [d]
r2125[0] [ms]
r2146[0] [d]
r2125[1] [ms]
r2146[1] [d]
r2125[7] [ms]
r2146[7] [d]
[8060.1]
Alarm 1
(oldest)
Alarm 2
Alarm 8
(most recent)
POWER ON
Alarm present
r2139.7
r2122[8]
r2122[9]
r2122[63]
r2124[8] [I32]
r2134[8] [Float]
r2124[9] [I32]
r2134[9] [Float]
r2124[63] [I32]
r2134[63] [Float]
r2123[8] [ms]
r2145[8] [d]
r2123[9] [ms]
r2145[9] [d]
r2123[63] [ms]
r2145[63] [d]
r2125[8] [ms]
r2146[8] [d]
r2125[9] [ms]
r2146[9] [d]
r2125[63] [ms]
r2146[63] [d]
Alarm 1
(most recent)
Alarm 2
Alarm 56
(oldest)
Alarm history
<1> The buffer parameters are updated cyclically in the background (see status signal in r2139).
<1>
Control Unit
Warning Present
r3114.9
r3121[63]
r3121[9]
r3121[8]
r3121[7]
r3121[1]
r3121[0]
Compo_no
alarm
r3123[63]
r3123[9]
r3123[8]
r3123[7]
r3123[1]
r3123[0]
Diag_attr
alarm
Содержание SINAMICS S110