Parameter
List of parameters
1-472
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Display and connector output for the integer number of the output signal for the function generator.
Dependency:
Refer to: p4816
Note:
The value is output independent of the function generator operating mode.
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
Description:
Sets the signal source to control the function generator.
When the function generator is running, signal generation is stopped with a 0 signal from BI: p4819 and p4800 is
set to 0.
Dependency:
Refer to: p4800
Description:
Sets the signal to be generated for the function generator.
Value:
1:
Square-wave
2:
Staircase
3:
Delta
4:
Binary noise - PRBS (Pseudo Random Binary Signal)
5:
Sine-wave
r4817
CO: Function generator output signal integer number / FG outp integ no.
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Integer32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4818
CO: Function generator output signal / FG outp_sig
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
0
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4819
BI: Function generator control / FG control
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
1
p4820
Function generator signal shape / FG signal shape
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
1 5