Parameter
List of parameters
1-584
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the enable signals for safety functions on processor 1 that are integrated in the drive.
Dependency:
Refer to: r9771, p9801
Note:
STO: Safe Torque Off
A change only becomes effective after a POWER ON.
Description:
Sets the enable signal for the "Safe Brake Control" (SBC) function on processor 1.
Value:
0:
Inhibit SBC
1:
Enable SBC
Dependency:
Refer to: p9802
Note:
The "Safe Brake Control" function is not activated until at least one safety monitoring function has been enabled
(i.e. p9501 not equal to 0 and/or p9601 not equal to 0).
It does not make sense to parameterize "no motor holding brake available" and enable "Safe Brake Control" (p1215
= 0, p9602 = p9802 = 1) if there is no motor holding brake.
It does not make sense to parameterize "motor holding brake the same as sequence control, connection via BICO"
and enable "Safe Brake Control" (p1215 = 3, p9602 = p9802 = 1).
It is not permissible to parameterize "motor holding brake without feedback signals" and enable "Safe Brake Con-
trol" (p1278 = 1, p9602 = p9802 = 1).
SBC: Safe Brake Control
Description:
Sets the PROFIsafe address for processor 1.
Dependency:
Refer to: p9810
p9601
SI enable, functions integrated in the drive (processor 1) / SI enable fct P1
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO (SH) via terminals (Control Unit)
enable
Enable
Inhibit
2810
02
Motion monitoring functions integr. in the
drive (Control Unit)
Enable
Inhibit
-
03
PROFIsafe (Control Unit) enable
Enable
Inhibit
-
p9602
SI enable Safe Brake Control (processor 1) / SI enable SBC P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
2814
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p9610
SI PROFIsafe address (processor 1) / SI PROFIsafe P1
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFE hex
0000 hex