List of parameters
Parameter
1-347
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the ramp-up time of the technology controller.
Dependency:
Refer to: p2252, p2258
Note:
The ramp-up time is referred to 100 %.
Description:
Sets the ramp-down time of the technology controller.
Dependency:
Refer to: p2252, p2257
Note:
The ramp-down time is referred to 100 %.
Description:
Sets the setpoint after the ramp-function generator of the technology controller.
Description:
Sets the time constant for the setpoint filter (PT1) of the technology controller.
p2257
Technology controller, ramp-up time / Tec_ctrl t_ramp-up
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
p2258
Technology controller ramp-down time / Tec_ctrl t_ramp-dn
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
r2260
CO: Technology controller setpoint after ramp-function generator /
Tec_ctr set aftRFG
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7958
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p2261
Technology controller setpoint filter time constant / Tec_ctrl set T
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
60.000 [s]
0.000 [s]