En
co
de
r ev
alu
at
ion
Fu
nction dia
g
ra
ms
2-
88
9
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g.
2
-1
23
473
0 – En
code
r in
terface,
send
sig
nals,
encod
ers 1
...
2
- 4730 -
Function diagram
8
7
6
5
4
3
2
1
fp_4730_98_eng.vsd
DO: SERVO
SINAMICS S110
03.03.08 V04.04.00
Encoder evaluation - Encoder interface, send signals, encoders 1 ... 2
From the measuring probe
evaluation
[4740.4]
Feedback signal of the active function (1 = function active)
r0481[n-1]
Enc Gn_ZSW
<1>
<1> Index [n-1] --> encoder n
Index [0] --> encoder 1
Index [1] --> encoder 2
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Status word from encoder n (n = 1, 2 or 3)
1 = Position actual value from function 1
1 = Position actual value from function 2
1 = Position actual value from function 3
1 = Position actual value from function 4
1 = Measuring probe 1 deflected (high signal)
1 = Measuring probe 2 deflected (high signal)
Reserved
1 = Acknowledge encoder fault active
Reserved (for reference point offset)
Absolute value is cyclically transferred
Encoder fault, the fault is in Gn_XIST2 (r0483)
Parking encoder active (i.e. the encoder is not operational)
Bit 0
Bit No.
Bit 12
Bit 13
Bit 14
Bit 15
Generated value
in Gn_XIST2
(and can be
read)
Encoder status bits
from the position sensing, encoder n
[4704.8]
to the sequence control for Gn_XIST2
[4704.5]
Position value 2 from encoder n
The contents of position actual value 2 (Gn_XIST2) at [4704] depends on Gn_STW and Gn_ZSW.
This can be done as follows:
- Undefined for a parking encoder (Gn_ZSW.14 = 1).
- For Gn_ZSW.15 = 1 the fault code for encoder faults is located here.
- Position actual value at the reference mark (for Gn_STW.7 = 0 and Gn_ZSW.4-7 > 0; with handshake).
- Position actual value due to flying measurement (for Gn_STW.7 = 1 and Gn_ZSW.4.7 > 0; with handshake).
- Cyclic absolute position value (free-running value, e.g. from the EQN absolute track (for Gn_ZSW.13 = 1).
4
3
2
1
Function
No.
For reference number and flying
measurement
reference mark 1 or measuring probe 1
reference mark 2 or measuring probe 1
reference mark 3 or measuring probe 2
reference mark 4 or measuring probe 2
PROFIdrive bit
Refer to [1020.7]
PROFIdrive sampling time
NOTE:
SINAMICS S110 supports only one encoder. This encoder may be parameterized as encoder 1 or encoder 2.