List of parameters
Parameter
1-323
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146, r3121, r3123
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the second status word of faults and alarms.
Description:
Displays the system runtime in days when the fault was removed.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2130, r2133, r3115, r3120, r3122
Notice:
The time comprises r2136 (days) and r2109 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the control word of the faults and alarms.
r2134[0...63]
Alarm value for float values / Alarm value float
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
8065
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2135.0...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
All objects
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2548
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Fault encoder 1
Yes
No
-
01
Fault encoder 2
Yes
No
-
12
Fault motor overtemperature
Yes
No
-
13
Fault power unit thermal overload
Yes
No
-
14
Alarm motor overtemperature
Yes
No
-
15
Alarm power unit thermal overload
Yes
No
-
r2136[0...63]
Fault time removed in days / t_flt resolv. days
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
8060
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
All objects
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2546
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
07
Acknowledge fault
Yes
No
-
10
External alarm 1 (A07850) effective
Yes
No
-
11
External alarm 2 (A07851) effective
Yes
No
-
12
External alarm 3 (A07852) effective
Yes
No
-
13
External fault 1 (F07860) effective
Yes
No
-