Parameter
List of parameters
1-532
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the encoder configuration for the redundant coarse position value.
The encoder that is used for the safe motion monitoring functions on processor 2 must be parameterized in this
parameter.
Dependency:
Refer to: r0474, p9515
Description:
Sets the configuration for the encoder and position actual value.
The encoder that is used for the safe motion monitoring functions on processor 2 must be parameterized in this
parameter.
Dependency:
Refer to: p0404, p0410, p9516
Description:
Sets the grid division for a linear encoder.
The encoder that is used for the safe motion monitoring functions on processor 2 must be parameterized in this
parameter.
Dependency:
Refer to: p9316
p9315
SI Motion coarse position value configuration (processor 2) / SI Mtn s config P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000
0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Incrementer
Yes
No
-
01
Encoder CRC least significant byte first
Yes
No
-
02
Redundant coarse position val. most signifi-
cant bit left-aligned
Yes
No
-
16
DRIVE-CLiQ encoder
Yes
No
-
p9316
SI Motion encoder configuration safety functions (processor 2) / SI Mtn enc cfg P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder rotating/linear
Linear
Rotating:
-
01
Position actual value, sign change
Yes
No
-
p9317
SI Motion linear scale grid division (processor 2) / SI Mtn grid P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [nm]
250000000.00 [nm]
10000.00 [nm]