List of parameters
Parameter
1-235
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: p1317, p1338, p1349
Note:
The filter time constant must be greater than the oscillation period of the oscillation to be dampened.
Description:
Sets the proportional gain for DC braking (p1230, p1231).
Dependency:
Refer to: p1346
Note:
Current controller adaptation is not effective for DC braking.
Description:
Sets the integral time for DC braking (p1230, p1231).
Dependency:
Refer to: p1345
Note:
For p1346 = 0, the following applies:
The integral time of DC braking is de-activated.
Description:
Sets the maximum output frequency for resonance damping for U/f control.
Resonance damping is inactive above this output frequency.
Dependency:
Refer to: p1338, p1339
Note:
Resonance damping is active in the following ranges:
- Active: 3.1 Hz ... p1349
- Build-up (linear): 3.1 ... 4.77 Hz
- Reduction (linear): 0.95 * p1349 ... p1349
Description:
Sets the configuration for the closed-loop speed control.
p1345[0...n]
DC braking proportional gain / DCBRK Kp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
V/f open-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 100000.000
0.000
p1346[0...n]
DC braking, integral time / DCBRK Tn
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
V/f open-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [ms]
50.000 [ms]
0.030 [ms]
p1349[0...n]
U/f mode resonance damping maximum frequency / Uf res_damp f_max
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
V/f open-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Hz]
3000.00 [Hz]
3000.00 [Hz]
p1400[0...n]
Speed control configuration / n_ctrl config
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
1590, 5490
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000
0011 1010 0000 bin