Parameter
List of parameters
1-410
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the task mode presently being processed.
Dependency:
Refer to: p2623
Description:
Displays the actual position for the following events:
- external block change via measuring probe (p2632 = 0, BI: p2661 = 0/1 signal).
- external block change via BI: p2633 (p2632 = 1, BI: p2633 = 0/1 signal).
- activate traversing task (BI: p2631 = 0/1 signal).
Dependency:
Refer to: p2631, p2632, p2633, p2661
Description:
Displays the clearance determined between the reference cam and zero mark in the search for reference.
Description:
Displays the currently effective velocity override.
Dependency:
Refer to: p2571, p2646
Note:
The effective override can differ from the specified override due to limits (e.g. p2571, maximum velocity).
r2677
CO: EPOS current task mode / Task mode cur
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2678
CO: EPOS external block change / Ext BlckChg s_act
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3615, 3616,
3620
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2680
CO: EPOS clearance, reference cam and zero mark / Clearance cam/ZM
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3612
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2681
CO: EPOS velocity override effective / v_over effective
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......