List of parameters
Parameter
1-45
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the effective Drive Data Set (DDS).
Dependency:
Refer to: p0820, r0837
Note:
The drive data set changeover is suppressed when selecting the motor identification, during the rotating measure-
ment, the encoder calibration and the friction characteristic record.
Description:
Displays the status word of the closed-loop control.
Note:
Re bit 04:
The bit is immediately set after power-on
Exception:
For an induction motor with brake (except for p1215 = 2), the bit is only set when 60% of the reference flux is
reached.
Description:
Displays the actual speed setpoint at the input of the speed controller or U/f characteristic (after the interpolator).
Dependency:
Refer to: r0020
Note:
The speed setpoint is available smoothed (r0020) and unsmoothed (r0060).
r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DDS eff., bit 0
ON
OFF
-
01
DDS eff., bit 1
ON
OFF
-
r0056.1...15
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2526
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
01
De-magnetizing completed
Yes
No
-
04
Magnetizing completed
Yes
No
2701
08
Field weakening active
Yes
No
-
14
Vdc_max controller active
Yes
No
-
15
Vdc_min controller active
Yes
No
-
r0060
CO: Speed setpoint before the setpoint filter / n_set before filt.
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2701, 2704,
5020, 6030, 6799
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]