Parameter
List of parameters
1-442
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Setting for coefficient K3 to calculate the characteristic (p4662).
Dependency:
Refer to: p4662, p4663, p4664, p4665
Description:
Sets the configuration for evaluation on the analog sensor.
Notice:
Re bit 06:
Setting the bit sets the velocity actual value (r0061) permanently to 0.
Re bit 13:
Setting the bit sets the commutation angle permanently to the commutation angle offset (p0431).
Note:
Re bit 09:
A setting of bit = 0 will trigger a fault for the relevant channel if the actual value is invalid.
A setting of bit = 1 will trigger an alarm for the relevant channel if the actual value is invalid.
Re bit 10, 11:
If both channels are activated, the actual value is generated from the mean value of both channels. If a channel fails
(actual value invalid), it is not included when the mean value is generated.
Description:
Sets the input circuit for the analog sensor.
Value:
0:
Differential
1:
Single-ended A, B
2:
Single-ended A*, B*
3:
Single-ended A, B sensitive
Note:
p4671 = 0:
The two signals on a track are evaluated differentially.
p4671 = 1:
Only the non-inverted signal on a track is evaluated.
p4666[0...n]
Encoder characteristic K3 / Enc char K3
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4670[0...n]
Analog sensor configuration / Ana_sens config
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
06
Set velocity to 0
Yes
No
-
08
Pos val range
0.0 / 1.0 pulse
-0.5 / +0.5 pulse
-
09
Fault/alarm messages
Alarm
Fault
-
10
Chann B act
Yes
No
-
11
Chann A act
Yes
No
-
13
Commutation angle constant
Yes
No
-
p4671[0...n]
Analog sensor input / Ana_sens inp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 3
0