List of parameters
Parameter
1-247
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the effective P gain of the speed controller.
Description:
Displays the effective integral time of the speed controller.
Description:
Sets the P gain for encoderless operation for the speed controller.
Note:
When automatically calculating the speed controller, only the motor moment of inertia is taken into account (p0341).
For higher load moments of inertia (p0342 > 1 or p1498 > 0), you are advised to check the speed controller gain.
Description:
Set the integral time for encoderless operation for the speed controller.
Description:
Sets the signal source to hold the integrator for the speed controller.
r1468
Speed controller P-gain effective / n_ctr Kp eff
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
5040, 5042,
5210
P-Group:
Closed-loop control
Units group:
17_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [Nms/rad]
- [Nms/rad]
- [Nms/rad]
r1469
Speed controller integral time effective / n_ctr Tn eff
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
5040, 5042,
6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
p1470[0...n]
Speed controller encoderless operation P-gain / n_ctrl SLVC Kp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
5210
P-Group:
Closed-loop control
Units group:
17_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [Nms/rad]
999999.000 [Nms/rad]
0.300 [Nms/rad]
p1472[0...n]
Speed controller encoderless operation integral time / n_ctrl SLVC Tn
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0 [ms]
100000.0 [ms]
20.0 [ms]
p1476[0...n]
BI: Speed controller hold integrator / n_ctrl integ stop
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5040,
5042, 5210, 6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......