List of parameters
Parameter
1-609
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the Safety Integrated status on processor 2.
Dependency:
Refer to: r9772
Notice:
If communication between processor 1 and processor 2 is interrupted, then this display parameter is no longer
updated. The last transferred status of processor 2 is displayed.
Note:
Re bit 00:
When STO is selected, the cause is displayed in bits 16 ... 18 and in bit 20.
Re bit 05:
When SS1 is selected, the cause is displayed in bits 22 and 23.
Re bit 18:
When the bit is set, STO is selected via PROFIsafe.
SMM: Safe Motion Monitoring
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on processor 2.
Dependency:
Refer to: r9780
r9872.0...24
CO/BO: SI status (processor 2) / SI Status P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2804
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO on Motor Module selected
Yes
No
2810
01
STO on Motor Module active
Yes
No
2810
02
SS1 delay time on Motor Module active
Yes
No
2810
03
Safe Brake Adapter feedback signal
Yes
No
2814
04
SBC requested
Yes
No
2814
05
SS1 selected on the Motor Module (Basic
Functions)
Yes
No
-
06
SS1 active on the Motor Module (Basic
Functions)
Yes
No
-
09
STOP A cannot be acknowledged, active
Yes
No
2802
10
STOP A active
Yes
No
2802
15
STOP F active
Yes
No
2802
16
STO cse: Safety comm. mode
Yes
No
-
17
STO cause selection via terminal (Basic
Functions)
Yes
No
-
18
STO cause: selection via SMM
Yes
No
-
20
STO cause selection PROFIsafe (Basic
Functions)
Yes
No
-
22
SS1 cause selection terminal (Basic Func-
tions)
Yes
No
-
23
SS1 cause selection PROFIsafe (Basic
Functions)
Yes
No
-
24
Slave Motor Module ready for communica-
tion
Yes
No
-
r9880
SI monitoring clock cycle (processor 2) / SI mon_clk cyc P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......