List of parameters
Parameter
1-721
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the signal source for the "accept setting value" signal of instant PT1 1 of the smoothing element.
Description:
Sets the smoothing time constant T in milliseconds of instance PT1 1 of the smoothing element.
Description:
Display parameter for the smoothed output quantity Y of instance PT1 1 of the smoothing element.
Description:
Setting parameter for the run-time group in which instance PT1 1 of the smoothing element is to be called.
Value:
0:
Run-time group 0
1:
Run-time group 1
2:
Run-time group 2
p20251
BI: PT1 1 accept setting value S / PT1 1 acc set val
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p20252
PT1 1 smoothing time constant in ms / PT1 1 T_smooth ms
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 340.28235E36
0.00
r20253
CO: PT1 1 output Y / PT1 1 output Y
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
-
p20254
PT1 1 run-time group / PT1 1 RTG
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 9999
9999