List of parameters
Parameter
1-441
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the characteristic type.
For non-linear sensors, the interrelationship between the signal voltage and the position can be defined using a
third degree polynomial.
Value:
0:
Characteristic inactive
1:
Characteristic polynomial third degree
Dependency:
Refer to: p4663, p4664, p4665, p4666
Note:
If value = 1:
A third degree polynomial is defined as follows:
F(x) = K3 * x^3 + K2 * x^2 + K1 * x + K0
Coefficients K0 ... K3 should be defined and entered into p4663 ... p4666.
The sensor range is emulated to x = -0.5 ... +0.5.
Description:
Setting for coefficient K0 to calculate the characteristic (p4662).
Dependency:
Refer to: p4662, p4664, p4665, p4666
Description:
Setting for coefficient K1 to calculate the characteristic (p4662).
Dependency:
Refer to: p4662, p4663, p4665, p4666
Description:
Setting for coefficient K2 to calculate the characteristic (p4662).
Dependency:
Refer to: p4662, p4663, p4664, p4666
p4662[0...n]
Encoder characteristic type / Enc char_type
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(4)
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p4663[0...n]
Encoder characteristic K0 / Enc char K0
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4664[0...n]
Encoder characteristic K1 / Enc char K1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4665[0...n]
Encoder characteristic K2 / Enc char K2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
FloatingPoint32
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-