List of parameters
Parameter
1-149
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the currently referred input value of the analog input.
When interconnected, the signals are referred to the reference quantities p200x and p205x.
Note:
AI: Analog Input
Description:
Sets the type of the analog input.
Value:
0:
Unipolar voltage input (0 V ... +10 V)
4:
Bipolar voltage input (-10 V ... +10 V)
Description:
Sets the scaling characteristic for the analog input.
The scaling characteristic for the analog input is defined using 2 points.
This parameter specifies the x coordinate (input voltage in V) of the 1st value pair of the characteristic.
Note:
The parameters for the characteristic do not have a limiting effect.
Description:
Sets the scaling characteristic for the analog input.
The scaling characteristic for the analog input is defined using 2 points.
This parameter specifies the y coordinate (percentage) of the 1st value pair of the characteristic.
Note:
The parameters for the characteristic do not have a limiting effect.
r0755
CO: CU analog input actual value in percent / CU AI value in %
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
p0756
CU analog input type / CU AI type
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 4
4
p0757
CU analog input characteristic value x1 / CU AI char x1
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-11.000 [V]
11.000 [V]
0.000 [V]
p0758
CU analog input characteristic value y1 / CU AI char y1
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2040
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-1000.00 [%]
1000.00 [%]
0.00 [%]