Page 72
Setup Menu
UVTOCSetup and System Configuration.fm
Section 5
5.2.3.4 Blowback On
The Blowback on period is the amount of time (0 to 100 seconds) that the
compressed air will be blown back through the inlet filter.
The blowback filter valve is an
optional device. Please contact your
manufacturer representative for
further information.
1.
To enter the Blowback on period screen, press the ENTER button after
setting the Blowback interval.
2.
Set the seconds.To change the displayed setting, press ENTER.
3.
Asterisks will flash on either side of the setting. Use the UP or DOWN
buttons to increase or decrease the setting.
4.
When the correct number of seconds are displayed, press ENTER to
place the value in memory.
5.2.4 Periods Screen
The periods of operation screen allows entry into a set of menus that control
the time periods associated with phases of the analyzer.
Enter the Periods screen by pressing the UP + DOWN button while in the
Times screen.
5.2.4.1 Pre Zero Period
The pre zero period is the number of minutes that the analyzer is switched to
the DI water port before attempting a zero baseline.
1.
Press the ENTER button while in the Periods screen. The Pre zero period
screen is displayed.
2.
To change the displayed setting, press ENTER.
3.
Asterisks will flash on either side of the setting. Use the UP or DOWN
buttons to increase or decrease the setting (1 to 60 minutes).
4.
When the desired delay time is displayed, press ENTER to place the
value in memory.
5.2.4.2 Pre Span Period
The pre span period is the number of minutes that the analyzer is switched to
the calibration STD port before attempting an autocalibration span.
B l o w b a c k o n
5s
P e r i o d s
P r e z e r o p e r i o d
7 m i n
Содержание 1950Plus
Страница 2: ...Page 2 4195M0040title page fm...
Страница 12: ...Page 12 Safety Precautions UVTOCSafety Precautions fm...
Страница 24: ...Page 24 EPA Mode UVTOCIntroduction fm...
Страница 26: ...Page 26 Installation UVTOCInstallation Stopper fm...
Страница 28: ...Page 28 Unpacking and Installation UVTOCUnpacking Installation Setup fm Section 2 Figure 6 Analyzer Dimensions...
Страница 54: ...Page 54 Storage and Handling Tips UVTOCReagents and Standards fm...
Страница 60: ...Page 60 Analyzer Adjustments UVTOCCommissioning fm...
Страница 62: ...Page 62 Operation UVTOCOperation Stopper fm...
Страница 110: ...Page 110 Maintenance UVTOCMaintenance Stopper fm...
Страница 128: ...Page 128 Replacing the Fuses UVTOCMaintenance fm...
Страница 137: ...Section 8 Page 137 UVTOCTroubleshooting and Service fm Service Menu Structure 8 5 Service Menu Structure...
Страница 146: ...Page 146 Fault ID Codes UVTOCTroubleshooting and Service fm...
Страница 152: ...Page 152 TC Conversion UVTOC_TC_conversion fm...
Страница 160: ...Page 160 Analyzer Pump Configurations UVTOC_PumpConfiguration fm...
Страница 164: ...Page 164 Glossary UVTOCGlossary fm...
Страница 172: ...Page 172 Replacement Parts UVTOCReplacement Parts fm...
Страница 176: ...Page 176 General Information UVTOCGeneral Information Stopper fm...
Страница 182: ...Page 182 4195M0040Certification fm Certification...