57
*1:
Registered in FOMA terminal by &W command.
*2:
Not reset by &F and Z commands.
*3:
When Z command is executed before the &W command, the terminal is reset to the last status registered in memory, and
prior changes are erased.
AT+CRC=<n>
*1
Sets whether to use +CRING result codes when communication is received.
n=0 : Does not use (default)
n=1 : Uses "+CRING: <type>" result codes
type=GPRS "PPP",,,"<APN>" : Packet communication
type=SYNC : 64K data communication
type=AV64K : 64K videophone
type=AV32K : 32K videophone
AT+CRC? : Displays current settings
AT+CRC=? : Displays a list of assignable values
AT+CRC=0
OK
AT+CREG=<n>
*1
Sets whether to display network information indicating Within service area or Out of
service area.
n=0 : Not notified (default)
n=1 : When the terminal is moved from Within service area to Out of service area or vice
versa, the status is reported in the "+CREG:<stat>" format.
stat=0 : Out of service area
stat=1 : Within service area
stat=4 : Unknown
AT+CREG? : Display the current settings and status in the "+CREG : <n>,<stat>" format
AT+CREG=? : Displays a list of assignable values
AT+CREG=0
OK
AT+GMI
Displays FOMA terminal manufacturer name.
AT+GMI
FUJITSU
OK
AT+GMM
Displays FOMA terminal product name.
AT+GMM
FOMA F903i
OK
AT+GMR
Displays FOMA terminal version in "VerX.XX" format.
AT+GMR
Ver1.00
OK
AT+IFC=<n,m>
*1
Sets how to control local flow between the PC and the FOMA terminal.
n : DCE by DTE
m : DTE by DCE
0 : No flow control
1 : Perform XON/XOFF flow control
2 : Perform RS/CS (RTS/CTS) flow control (default)
AT+IFC? : Displays current settings
AT+IFC=? : Displays a list of assignable values
AT+IFC=2,2
OK
AT+WS46=<n>
Sets wireless network used when sending communication. Does not affect send operation.
n=22 : FOMA network (fixed value)
AT+WS46? : Displays current settings
AT+WS46=? : Displays a list of assignable values
AT+WS46=22
OK
AT
¥
S
Displays the currently set commands and S register settings.
AT
¥
S
E1 Q0 V1 X4 &C1 &D2 &S0
・・・
(snip)
・・・
S104=001
OK
AT
¥
V<n>
*1
Sets type of response codes used when connection is made.
n=0 : Does not use expanded result codes (default)
n=1 : Uses expanded result codes
AT
¥
V0
OK
+++
Moves from online data mode to online command mode when entered during a
communication.
The escape guard interval is 1 second (fixed value).
+++ (not displayed)
OK
Upper slot: Command
Lower slot: Example
Description
Содержание F903i' 06.10
Страница 186: ......
Страница 301: ...299 Full Browser Viewing websites for PCs Full Browser 300 Setting for Full Browser 304 ...
Страница 412: ......
Страница 430: ......
Страница 485: ...483 INDEX Quick Reference Manual INDEX 484 Quick Reference Manual 490 ...
Страница 519: ...18 2 Select パケット通信 Packet communication and click 次へ Next 3 Select その他 Others and click 次へ Next 4 Click OK ...
Страница 563: ...Kuten Code List CA92002 4966 ...