Safety function blocks
440
02/16 MN05013001Z EN
Coils and contacts
Function block coils initiate the functions of the function
block and monitor the connected safety transmitters.
The contacts of a safety function block confirm the enable
conditions present, selected operating modes or indicate
errors.
Coils
The OM..SA function block coil is used to start the moni-
toring function of the function block.
Associate the coil here for example with the enable contact
of another safety function block.
The Reset coil OM..RE resets the function block in Manual
Start (MST) and Controlled Start (CST) operating modes and
starts normal operation. It is used in the safety circuit
diagram.
The function block is enabled either in the safety circuit
diagram or in the standard circuit diagram via its enable coil
OM..EN.
Coil
Function
OM..SA
Safety activation of the function block
OM..RE
Reset
OM..EN
Function block enable