Standard function blocks
284
02/16 MN05013001Z EN
Number range of the BCD code
The BCD code only allows the number range 0
.
to 9. Values
greater than 9 are processed as 9.
Input
Assign the input value to be converted to function block
input >I1.
The function block input >I1 knows the following operands:
• Constant.
• Markers MD, MW, MB.
• Output …QV> of a different function block.
BCD code
Decimal value
0000
0
0001
1
0010
2
0011
3
0100
4
0101
5
0110
6
0111
7
1000
8
1001
9
1010 - 1111
Not permissible
0001 0000
10
1001 1001
99
Parameters
Function
>I1
Input value:
Decimal: -161061273 - +161061273
BCD: -9999999 - +9999999