Safety function blocks
452
02/16 MN05013001Z EN
Output
Diagnostics output DG: Provides information the states of
the function block. It is evaluated in the standard circuit
diagram e. g. with the diagnostics function block.
Table 18:
Diagnostics-/-Error codes
Further information on this output is provided in section
“Common features”, page 348.
Parameters
Function, parameterisation in the func-
tion block
DG:
Diagnostics: double word
Status number
Plain text
Hexadecimal (0–F)
decimal (0-9)
0000
0000
No Enable.
200A
8202
Operating mode can be selected.
802A
32810
Operating mode 1 selected (Q1 = 1).
802B
32811
Operating mode 2 selected (Q2 = 1).
802C
32812
Operating mode 3 selected (Q3 = 1).
802D
32813
Operating mode 4 selected (Q4 = 1).
802E
32814
Operating mode 5 selected (Q5 = 1).
803A
32826
Operating mode 1 fixed (Q1 = 1).
803B
32827
Operating mode 2 fixed (Q2 = 1).
803C
32828
Operating mode 3 fixed (Q3 = 1).
803D
32829
Operating mode 4 fixed (Q4 = 1).
803E
32830
Operating mode 5 fixed (Q5 = 1).
F014
61460
Error: More than one operating mode selected at the
same time.
F015
61461
Error: No operating mode selected.