BT, data block transfer
197
02/16 MN05013001Z EN
Wiring of the function block
You wire the function block in the standard circuit diagram
with its trigger coil and its contacts. Example of a block
transfer function block:
Figure 79:
Wiring the trigger coil
The trigger coil is connected to a device input.
Figure 80:
Wiring the contacts
The messages of the function block are sent as a group
message to a marker.
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
The parameters consist of the following:
IS05--------------------------
Ä
BT07T
_
BT07E1
o
BT07E2
s
BT07E3
j
-----------------------
Ä
M 42
BT07 INI +
>I1
>I2
>NO
BT07
Function block: Data block transfer, number 07
INI
Mode: INI
+
Parameter display: Call enabled
>I1
Source range start
>I2
Destination range start
>NO
Number of elements to be written in bytes per range