JC, conditional jump
269
02/16 MN05013001Z EN
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
Coil
The coil of the function block is used in the standard circuit
diagram to activate the function block.
Contact
The contact of the function block is evaluated in the standard
circuit diagram. It indicates a fault if there is not an
associated jump present or is in front of the jump location
(backward jump).
Memory requirement
The conditional jump function block requires 20 bytes of
memory.
JC01 +
JC01
Function block: Conditional jump, number 01
+
Without function
Parameters
Function
JC..EN
Selective activation of the function block
Parameters
Function
JC..E1
Fault signal