OM, Maximum speed moni-
toring
443
02/16 MN05013001Z EN
Error detection and acknowledgement
The function block detects when the maximum permissible
rotation frequency is exceeded, as well as the failure of the
sensors at device terminals IS1 and IS2.
General information on Errors and how the easySafety reacts
to them is provided in section “Diagnostics using the ER
contact” on page 622.
h
The maximum permissible rotation frequency on device
inputs IS1 and IS2 is 1000 Hz.
Error
Error acknowledgement
Maximum permis-
sible rotation
frequency exceeded
Drop out of coil OM..SA for activation of
the safety function block
Failure of sensors
Drop out of coil OM..SA for activation of
the safety function block