LM, light curtain muting
425
02/16 MN05013001Z EN
The synchronization time ST must be set very low as this
muting process requires the parallel triggering of both
muting sensors A1 and A2 as well as B1 and B2.
Muting sensors parameter: 2S
Sequential muting with 2 sensors enables a group of muting
sensors arranged in sequence to detect the start of the
movement of the transported goods.
Figure 214:
Light curtain for muting: Sequential muting with 2
muting sensors
With this signal sequence, only the direction of motion A1 -
> A2 is permissible:
The sensors are connected to the function block coils LM..A1
and LM..A2.
The protective function of the light curtain is reactivated
after the transported material leaves the light curtain.