02/16 MN05013001Z EN
blocks and clock synchronization with SC standard func-
tion blocks.
• Continuous communication through the multi-function
interface for online status indication with easySoft-Safety.
• Continuous communication through the easyLink connec-
tion and a communication expansion device.
• Configuration with OM and ZM safety function blocks for
frequency measurement, at a rotational frequency of
950 Hz.
Example
Figure 295:
Circuit diagram in easySafety
1) The circuit diagram in easySafety has six rungs (five
programmed rungs + an empty rung).
2) According to Table 30 the maximum circuit diagram
processing time for this is 100 ms.
3) Since the calculated circuit diagram processing time is
shorter than the error detection time, the following
applies in regard to this device with transistor outputs:
Reaction time
= error detection time (150 ms) + output
delay (1 ms) =
151 ms
IS09---------------------------
Ä
ES01I1
IS10---------------------------
Ä
ES01I2
IS13---------------------------
Ä
ES01RE
ES01QS------------------------
uÄ
QS01
hÄ
QS03