A
pp
en
di
x D
: W
or
ki
ng W
ith H
yb
ri
ds •
15
5
©2016 Axia Audio- Rev 1.8.1
can configure a show profile named “WXYZ”
and specify that it connect with an Nx12 that
controls the call in lines wired directly to that
unit. Another show profile, “WABC,” has settings
to control an Nx6 handling POTS request lines
wired to it. Using this new capability, you can
define a different phone system to control for
each Show Profile, if you wish, tailored to spe-
cific on-air needs.
You will need to know the following things in order
to configure Element for use with your phone system:
1. The IP address of your Telos phone system(s)
2. The user name and password of your phone system(s)
3. The name of the phone system Show you wish to
connect to.
Configuring the Element Show Profile
The major change to Element phone configuration is
that the IP address of your Telos phone system must be
entered in the Phone section of your Element or Power-
Station Show Profile, instead of in the Phone Channel
section as was previously required. The phone system IP
address is now stored in Element’s Show Profile settings,
allowing you to create different show profiles which
connect to different Telos devices.
1. Enter the Telos phone system’s IP address. Navi-
gate to Element’s
Sources and Profiles
page. Se-
lect the Element Show Profile you wish to config-
ure, and click on
Phone
.
In the
Phone URL
field, enter the IP address of
the Telos phone system you’re connecting to. The
format begins with ap: (to define that you will be
using the AP protocol) followed by a login, a pass-
word, and finally the IP address.
In Figure D-6, the user is telos, the password
is telos and the IP address follows, like so:
2. Configure the Show. In the same screen where you
entered the IP address of your Telos phone system,
enter the Telos Show running on that device. In the
screenshot example, the show is called “Hybrid
1&2.” If the Nx12 was configured for two shows, an-
other show could have been “Hybrid 3&4.” Refer to
the configuration of your Telos device to determine
which show name you need to enter into this field.
Possible shows from a Telos TWOx12 are “Hy-
brid1&2”, “Hybrid1”, and “Hybrid2”. Possible
shows from an Nx6 or NX12 are “Hybrid 1&2”,
“Hybrid 3&4”, and “Hybrid 1-4”. Telos Series 2101
show names are generated in the configuration of the
system. Again, it is important that you refer to your
Telos device to determine which show is running.
The
Host / Studio Name
field can remain blank.
A
Show Password
is used only if there is a pass-
word assigned to the Show of your Telos unit. Other-
wise, leave this field blank.
3. Configure other options. Element’s Call Controller
module uses the left row of telephone line selection
buttons to control Hybrid 1, the right row to control
Hybrid 2. If you wish to use the right row of Call Con-
troller buttons to control Hybrid 1 and the left row to
control Hybrid 2, click the
Reversed Hybrid
box.
Some Telos products provide support for up to
24 lines. You can select either
Auto
,
12 Lines
or
24 Lines
with the
Mode Selection
radio
buttons. In 12-line mode, 12 lines are displayed
on both columns of the Call Controller module;
the left key bank answers lines on Hybrid 1, the
right keys answer lines on Hybrid 2. In 24-line
mode, both left and right key banks will answer
lines using Hybrid 1. To answer lines on any
other hybrid, operators will use the module’s
SET
key to choose which hybrid to use. Select-
Figure D-6: Setting connections
Содержание element v.2.0
Страница 100: ...5 Element Operations 90 2016 Axia Audio Rev 1 8 1 Capital budget may you never decrease for we need new test gear...
Страница 149: ...Appendix A Specifications 139 2016 Axia Audio Rev 1 8 1...
Страница 183: ...Warranty 173 2016 Axia Audio Rev 1 8 1 TCP IP How did we live without thee Analogicly...
Страница 184: ...THIS PAGE INTENTIONALLY LEFT BLANK...