Setting Measurement Conditions
Setting Stimulus Conditions
Setting power level with Auto Power Range set function
When the Auto Power Range set function is effective, the proper source attenuator and
power range are selected automatically, as shown by the figures below, according to the
maximum frequency and maximum output power of each channel (except for instruments
with option 213, 313, or 413).
NOTE
Under the following conditions, turn OFF the Auto Power Range set function and set the
power range and power level manually, according to
•
When different power ranges are selected in multiple channel measurement settings. In
this case, an error message is displayed to avoid source attenuator damage. (For
example: When Channel 1’s stop frequency is 8 GHz and Channel 2’s stop frequency is
2 GHz with a 0 dBm setting, the error message “Continuous switching may damage
source attenuator” is displayed because each selected power range is different.
•
When you cannot obtain the desirable power sweep range. (For example, if you want to
set start power to - 25 dBm and stop power to 7 dBm at 2 GHz CW, you cannot set the
start power level below - 20 dBm when Auto Power Range set function is ON.)
Figure 3-5
Available power level and selected power range with Auto Power Range set function
ON (when maximum frequency is 3 GHz or below)
Содержание E5070B
Страница 6: ......
Страница 30: ...24 Contents ...
Страница 34: ...28 Chapter1 Precautions Before contacting us ...
Страница 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Страница 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Страница 479: ...473 14 Controlling E5091A 14 Controlling E5091A This chapter explains how to control the E5091A multiport test set ...
Страница 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Страница 604: ...598 AppendixA Manual Changes Manual Changes Figure A 12 Two port Touchstone file Figure A 13 Three port Touchstone file ...
Страница 634: ...628 AppendixB Troubleshooting Warning Message ...
Страница 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Страница 740: ...734 AppendixE General Principles of Operation Data Processing ...
Страница 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...