![Agilent Technologies E5070B Скачать руководство пользователя страница 686](http://html.mh-extra.com/html/agilent-technologies/e5070b/e5070b_user-manual_2868065686.webp)
680
Appendix D
Softkey Functions
Calibration Menu
(Continued)
Modify Cal Kit
Specify CLSs
Thru
Displays softkeys for setting the THRU standard class.
Set All
Displays softkeys for selecting standard for the THRU standard class that applies to all test ports.
None
Does not include
1. (Std Name)
in the THRU standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,0
1. (Std
Name)
Includes
2. (Std Name)
in the THRU standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,1
.
.
.
.
.
.
21. (Std
Name)
Includes 21.( Std Name) in the THRU standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:THRU
x,y,21
Cancel
Returns to the softkey display screen one level higher.
Port 1-2
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 2. The
lower-level softkeys are the same as those for
Set All
.
Port 1-3
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 3. The
lower-level softkeys are the same as those for
Set All
.
Port 1-4
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 1 and 4. The
lower-level softkeys are the same as those for
Set All
.
Port 2-3
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 2 and 3. The
lower-level softkeys are the same as those for
Set All
.
Port 2-4
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 2 and 4. The
lower-level softkeys are the same as those for
Set All
.
Port 3-4
Displays softkeys for selecting standards for the THRU standard class that applies to test ports 3 and 4. The
lower-level softkeys are the same as those for
Set All
.
Return
Returns to the softkey display screen one level higher.
TRL Thru
Displays softkeys for setting the TRL THRU standard. The
lower-level softkeys displayed are the same as those for
Thru
.
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLT
TRL Reflect
None
Does not include
1. (Std Name)
in the TRL reflection standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR 0
1. (Std Name)
Includes
1. (Std Name)
in the TRL reflection standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR 1
.
.
.
.
.
.
21. (Std
Name)
Includes
21. (Std Name)
in the TRL reflection standard class.
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLR
21
Cancel
Returns to the softkey display screen one level higher.
TRL Line/Match
Displays softkeys for setting the TRL LINE/MATCH standard. The
lower-level softkeys displayed are the same as those for
Thru
.
:SENS{1-16}:CORR:COLL:CKIT:ORD:TRLL
Return
Returns to the softkey display screen one level higher.
TRL Option
Displays softkeys for setting the TRL calibration.
Impedance
Selects the reference impedance.
:SENS{1-16}:CORR:COLL:CKIT:TRL:IMP
Reference Plane
Selects the measurement data for the standard used to calculate the
reference plane.
:SENS{1-16}:CORR:COLL:CKIT:TRL:RPL
Return
Returns to the softkey display screen one level higher.
Key Operation
Function
SCPI Command
Содержание E5070B
Страница 6: ......
Страница 30: ...24 Contents ...
Страница 34: ...28 Chapter1 Precautions Before contacting us ...
Страница 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Страница 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Страница 479: ...473 14 Controlling E5091A 14 Controlling E5091A This chapter explains how to control the E5091A multiport test set ...
Страница 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Страница 604: ...598 AppendixA Manual Changes Manual Changes Figure A 12 Two port Touchstone file Figure A 13 Three port Touchstone file ...
Страница 634: ...628 AppendixB Troubleshooting Warning Message ...
Страница 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Страница 740: ...734 AppendixE General Principles of Operation Data Processing ...
Страница 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...