![Agilent Technologies E5070B Скачать руководство пользователя страница 340](http://html.mh-extra.com/html/agilent-technologies/e5070b/e5070b_user-manual_2868065340.webp)
334
Chapter 9
Analysis in Time Domain (Option 010)
Transformation to time domain
Transformation to time domain
The transformation function lets you transform a response in the frequency domain to the
corresponding response in the time domain.
Measurement flow
Table 9-1
Flow of transformation to time domain
Item
Description
“Selecting a type” on
page 335
Selects the transformation type from the following.
•
Band pass mode
You can set the sweep range arbitrarily. This is suitable for devices through
which signals within a certain frequency range pass such as filters.
•
Low pass mode
Simulates the TDR measurement. This mode is suitable for devices through
which dc current or signals of many frequencies pass, such as cables.
The low pass mode provides two types of modes: low pass step and low
pass impulse.
“Setting the window” on
page 337
Sets the window to reduce the ringing phenomenon, in which a waveform’s
waves are caused due to the fact that the frequency domain is finite.
“Calculating necessary
measurement conditions” on
page 338
Calculates the following values to obtain the necessary resolution and
measurement range in the time domain.
•
Sweep range
•
Number of points
•
Window width
“Setting the frequency range
and the number of points” on
page 342
Sets the sweep range and the number of points to the values calculated above.
“Setting display range” on
page 343
Sets the range displayed on the graph.
“Enabling transformation
function” on page 343
Enables the transformation function.
Table 9-1 shows the measurement flow of this transformation.
Содержание E5070B
Страница 6: ......
Страница 30: ...24 Contents ...
Страница 34: ...28 Chapter1 Precautions Before contacting us ...
Страница 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Страница 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Страница 479: ...473 14 Controlling E5091A 14 Controlling E5091A This chapter explains how to control the E5091A multiport test set ...
Страница 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Страница 604: ...598 AppendixA Manual Changes Manual Changes Figure A 12 Two port Touchstone file Figure A 13 Three port Touchstone file ...
Страница 634: ...628 AppendixB Troubleshooting Warning Message ...
Страница 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Страница 740: ...734 AppendixE General Principles of Operation Data Processing ...
Страница 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...