Appendix D
685
Softkey Functions
Calibration Menu
D. Sof
tke
y
Fu
nctions
(Continued)
Mixer/Converter
Calibration
Displays the softkey to execute a scalar-mixer calibration.
Scalar Cal (Manual)
Displays the softkey to execute a scalar-mixer calibration by using the calibration kits.
Select Ports
Displays the softkey to select test ports and calibration methods you want to use.
Port 1
Select 1-port calibration for the test port 1.
:SENS{1-16}:CORR:OFFS:COLL:METH:
SOLT1
:
:
:
Port 4
Select 1-port calibration for the test port 4.
:SENS{1-16}:CORR:OFFS:COLL:METH:
SOLT1
2-1 (fwd)
Select a scalar-mixer calibration for test port 1
→
2 (forward).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
1-2 (rev)
Select a scalar-mixer calibration for test port 2
→
1 (reverse).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
2,1 (both)
Select a scalar-mixer calibration for test port 1
→
2 and 2
→
1 (both
directions).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
:
:
:
4-3 (fwd)
Select a scalar-mixer calibration for test port 3
→
4 (forward).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
3-4 (rev)
Select a scalar-mixer calibration for test port 4
→
3 (reverse).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
3,4 (both)
Select a scalar-mixer calibration for test port 3
→
4 and 4
→
3 (both
directions).
:SENS{1-16}:CORR:OFFS:COLL:METH:
SMIX2
Cancel
Returns to the softkey display in one level higher.
Reflection
Displays the softkey to execute standard (OPEN, SHORT, and LOAD) measurements.
Port x @
Freq x
[Open]
Executes an OPEN reflection calibration on test port x by using the
frequency that is set in test port x. The x changes by the selected
test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:OPEN
Port x @
Freq y
[Open]
Executes an OPEN reflection calibration on test port x by using the
frequency that is set in test port y. The x and y change by the
selected test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:OPEN
Port x @
Freq x
[Short]
Executes a SHORT reflection calibration on test port x by using the
frequency that is set in test port x. The x changes by the selected
test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:SHOR
Port x @
Freq y
[Short]
Executes a SHORT reflection calibration on test port x by using the
frequency that is set in test port y. The x and y change by the
selected test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:SHOR
Port x @
Freq x
[Broadband]
Executes a LOAD reflection calibration on test port x by using the
frequency that is set in test port x. The x changes by the selected
test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:LOAD
Port x @
Freq y
[Broadband]
Executes a LOAD reflection calibration on test port x by using the
frequency that is set in test port y. The x and y change by the
selected test port and calibration method.
:SENS{1-16}:CORR:OFFS:COLL:LOAD
:
:
:
Return
Returns to the softkey display in one level higher.
Key Operation
Function
SCPI Command
Содержание E5070B
Страница 6: ......
Страница 30: ...24 Contents ...
Страница 34: ...28 Chapter1 Precautions Before contacting us ...
Страница 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Страница 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Страница 479: ...473 14 Controlling E5091A 14 Controlling E5091A This chapter explains how to control the E5091A multiport test set ...
Страница 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Страница 604: ...598 AppendixA Manual Changes Manual Changes Figure A 12 Two port Touchstone file Figure A 13 Three port Touchstone file ...
Страница 634: ...628 AppendixB Troubleshooting Warning Message ...
Страница 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Страница 740: ...734 AppendixE General Principles of Operation Data Processing ...
Страница 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...