Appendix C
Humphrey Field Analyzer II - i
Confidential and Proprietary
Field Service Guide
C - 2
52235C1105
TESTS THAT CAN BE TRANSFERRED USING EITHER SERIAL I OR II TRANSFER
MODE:
1.
Macula
2.
Central 10-2 Threshold
3.
Central 24-2 Threshold
4.
Central 30-2 Threshold
5.
Peripheral 60-4 Threshold
6.
Nasal Step Threshold
7.
Armaly Central Screening
8.
Armaly Full Field Screening
9.
Nasal Step Screening
10.
Central 40 Screening
11.
Central 76 Screening
12.
Central 80 Screening
13.
Peripheral 68 Screening
14.
Full Field 81 Screening
15.
Full Field 120 Screening
16.
Full Field 246 Screening
17.
Blindengeldgutachten (German visual
disability test)
18.
Fuehrerscheingutachten (German
driver’s license test)
19.
Esterman Monocular
20.
Esterman Binocular
21.
Kinetic Tests
(Serial II mode only)
TESTS THAT WILL NOT BE TRANSFERRED USING EITHER SERIAL I OR II
TRANSFER MODE:
Fast Threshold tests or Master files.
•
Compared, Averaged, or Merged exams.
•
Tests without birthdates, or with invalid birthdates.
•
Tests with invalid test dates.
•
Tests without
LEFT
or
RIGHT
denoted in eye field.
•
Tests that have invalid (x,y) coordinates for test points.
C.2
Installing the Serial I or the Serial II Transfer Disk
Installing the Serial I or the Serial II Transfer Disk can be done by the customer or service
engineer.
1)
Starting at the
Main Menu
, select the
Setup
icon.
2)
Select the
Additional Setup
menu.
3) Select
Install Software
.
4)
When the “Insert an HFA optional software floppy disk then pres OK to begin installation”
dialogue appears, insert the Serial I Transfer disk or the Serial II Transfer disk and press
the OK button.
5)
When the “Installing Revision XXX“ Press OK to Continue” dialogue appears, press OK.
6)
After a few seconds the “Optional software installation successful” dialogue appears,
Press OK.
NOTE:
It is not necessary to restart the instrument for the new software to become active. The
new features will become active after installation.
Summary of Contents for humphrey HFA II-i series
Page 4: ......
Page 179: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 424: ...Page 4 FA2i 013A PROPRIETARY and CONFIDENTIAL...
Page 502: ...FA2i 041 Page 3 Figure 2 Press rectangle in Top Left corner...
Page 516: ...Page 2 FA2i 046 Figure 1 Glass Film Wedge Detectors P N 67417 Note Spacing Washer Placement...
Page 517: ...FA2i 046 Page 3 Figure 2 Y Motor Turret Detector P N 67418 Note Spacing Washer Placement...