Chapter 15 Interrupt Controller
15-36
Bit Mnemonic Field
Name
Explanation
Read/Write
9
IS9
Interrupt Status 9
IRINTREQ [9] status
This bit indicates the status of SIO [1] interrupts.
1: Interrupt requests
0: No interrupt requests
R
8
IS8
Interrupt Status 8
IRINTREQ [8] status
This bit indicates the status of SIO [0] interrupts.
1: Interrupt requests
0: No interrupt requests
R
7
IS7
Interrupt Status 7
IRINTREQ [7] status
This bit indicates the status of external INT [5] interrupts.
1: Interrupt requests
0: No interrupt requests
R
6
IS6
Interrupt Status 6
IRINTREQ [6] status
This bit indicates the status of external INT [4] interrupts.
1: Interrupt requests
0: No interrupt requests
R
5
IS5
Interrupt Status 5
IRINTREQ [5] status
This bit indicates the status of external INT [3] interrupts.
1: Interrupt requests
0: No interrupt requests
R
4
IS4
Interrupt Status 4
IRINTREQ [4] status
This bit indicates the status of external INT [2] interrupts.
1: Interrupt requests
0: No interrupt requests
R
3
IS3
Interrupt Status 3
IRINTREQ [3] status
This bit indicates the status of external INT [1] interrupts.
1: Interrupt requests
0: No interrupt requests
R
2
IS2
Interrupt Status 2
IRINTREQ [2] status
This bit indicates the status of external INT [0] interrupts.
1: Interrupt requests
0: No interrupt requests
R
1
IS1
Interrupt Status 1
IRINTREQ [1] status
This bit indicates the status of TX49 Write Timeout Error interrupts.
1: Interrupt requests
0: No interrupt requests
R
0
IS0
Interrupt Status 0
IRINTREQ [0] status
This bit indicates the status of ECC Error interrupts.
1: Interrupt requests
0: No interrupt requests
R
Figure 15.4.14 Interrupt Source Status Register (3/3)
Summary of Contents for TX49 TMPR4937
Page 1: ...64 Bit TX System RISC TX49 Family TMPR4937 Rev 2 0 ...
Page 4: ......
Page 13: ...Table of Contents ix TMPR4937 Revision History 1 ...
Page 14: ...Table of Contents x ...
Page 15: ...Handling Precautions ...
Page 16: ......
Page 18: ...1 Using Toshiba Semiconductors Safely 1 2 ...
Page 40: ...3 General Safety Precautions and Usage Considerations 3 18 ...
Page 42: ...4 Precautions and Usage Considerations 4 2 ...
Page 43: ...TMPR4937 2005 3 Rev 2 0 ...
Page 44: ......
Page 52: ...Chapter 1 Overview and Features 1 6 ...
Page 156: ...Chapter 7 External Bus Controller 7 56 ...
Page 491: ...Chapter 16 Removed 16 1 16 Removed ...
Page 492: ...Chapter 16 Removed 16 2 ...
Page 493: ...Chapter 17 Removed 17 1 17 Removed ...
Page 494: ...Chapter 17 Removed 17 2 ...
Page 495: ...Chapter 18 Removed 18 1 18 Removed ...
Page 496: ...Chapter 18 Removed 18 2 ...
Page 497: ...Chapter 19 Removed 19 1 19 Removed ...
Page 498: ...Chapter 19 Removed 19 2 ...
Page 506: ...Chapter 20 Extended EJTAG Interface 20 8 ...
Page 530: ...Chapter 22 Pinout and Package Information 22 10 ...
Page 542: ...Chapter 24 Parts Number when Ordering 24 2 ...