4.1.1.1.2 Servo Drive Output
AC Power: P = I
・
U
・
U
≤
・
I
is limited by the Servo Drive
by the Motor
Note
in continuous
rated
operation
Continuous current
Continuous current Thermal limit on any component that has
to carry current. (FETs and motor
windings)
in continuous
stall operation
Continuous current
Continuous stall
current
Similar thermal limit as in continuous
rated operation.
Since there are no iron losses here, the
motor can stand a bit more.
in max
intermittent
operation
Max intermittent
current
Max intermittent
current
Max current can be applied for a short
time only (e.g. 250 ms).
Exceeding it would immediately burn the
windings.
AC
RMS
RMS
RMS
voltage
RMS
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01