3.1.9.1.86 0x603F Error code
Provides the error code of the last error which occurred. See object
0x203F Error report
for a more
detailed description.
Error
Code
Meaning
0x2220
Continuous over current (device
internal)
0x2250
Short circuit (device internal)
0x2350
Load level fault (I2t, thermal state)
0x2351
Load level warning (I2t, thermal state)
0x3130
Phase failure
0x3131
Phase failure L1
0x3132
Phase failure L2
0x3133
Phase failure L3
0x3210
DC link over-voltage
0x3220
DC link under-voltage
0x3331
Field circuit interrupted
0x4210
Excess temperature device
0x4310
Excess temperature drive
0x5300
Operating unit
0x6010
Software reset (watchdog)
0x6320
Parameter error
0x7121
Motor blocked
0x7300
Sensor
0x7500
Communication
Name
Index:Sub Type
Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access
PDO
Mapping
Error code
0x603F:0
UINT
16
0
readonly
(default)
Transmit
PDO
(Inputs)
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
880/1031