BisSloLo
BiSS data (SLO)
is permanently
Low.
The SLO line should be
set to high by the BiSS
slave when it is ready to
establish
communication. This
error usually happens
when there is some issue
with the power or
communication link, e.g.
one of the wires is
broken or not well
connected.
0x7303,
0x7304
BisFrame
BiSS Frame
configuration
error.
The sensor configuration
causes an issue related
to the BiSS frame. This
error is currently raised
only if the BiSS frame
size is higher than 64
bits.
0x7303,
0x7304
Please check the sensor
configuration according to the
documentation of the encoder
manufacturer. The most relevant
objects to check:
1. Resolution, unit Inc/ Revolution
2. Multiturn resolution, unit
number of bits
3. Number of filling bits, unit
number of bits
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
804/1031