3.1.9.1.129 0x60A9 SI unit velocity
Indicates the user-defined velocity units. Only the prefix is used by the firmware to scale the velocity; the
second and third bytes are always fixed to RPM (0xB447).
The supported values are:
1 RPM
(value 0x00B44700 or 11814656) - default, but may not be precise enough for some
applications.
0.1 RPM
(value 0xFFB44700 or 4290004736)
0.01 RPM
(value 0xFEB44700 or 4273227520)
0.001 RPM
(value 0xFDB44700 or 4256450304)
Configurations with a gearbox may find
0.001 RPM
is more appropriate.
Name
Index:Sub Type
Bit
Size
Options
Unit Access
PDO
Mapping
SI unit velocity
0x60A9:0
UDINT
32
RPM
11814656
0.1
RPM
4290004736
0.01
RPM
4273227520
0.001
RPM
4256450304
readwrite
Synapticon Documentation