Example: Using the position profile
set the profile objects:
Profile Velocity 0x6081
Profile acceleration 0x6083
Profile deceleration 0x6084
Quick Stop deceleration 0x6085
set mode of operation to 1
Set target position
Switch the drive to “Operation Enabled”
Set bit 5 of the controlword:
Set bit 4 of the controlword:
The drive will acknowledge the new target position on the rising edge of bit 4 by activating the
statusword bit 12 Set-point acknowledge for several cycles.
The motor will start rotating immediately.
Note
Setting the bits 4 and 5 of the controlword has to be done in the same order shown above or
simultaneously.
3.1.8.2.2.1.6 Parameters
Quick Stop deceleration 0x6085
The maximum possible speed of the Motor according to the data sheet.
Software position limit 0x607D
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
641/1031