ExAnSnsr
External Scaled
Analog Sensor
Output
exceeded one
of the
threshold
values.
This fault is triggered
when the scaled external
analog sensor output
exceeds the upper level
threshold or becomes
lower than the lower
level threshold.
0x2038:11 External
scaled measurement
Upper level threshold
0x2038:12 External
scaled measurement
Lower level threshold
0x7300 Please make sure that the upper
and lower level threshold values
are suitable for the sensor you
have connected and that the
values have been caluclated
according to the instructions given
in the documentation for scaled
measurements.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
822/1031