background image

INSTRUCTIONS

STL200H/L, STL200HB/L INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

Fig: 1

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside. 
CAUTION: TURN OFF ALL POWER AT CIRCUIT BREAKER/FUSE PANEL. The total lighting load connected to Stealth must not 
exceed 8 amps 120-277V (LED load). To switch more wattage an electrician can install a relay. Line Carrier Remote Control 
Systems such as X-10 or Leviton are incompatible with sensors and cause false activations. 
DO NOT INSTALL SENSORS ON A CIRCUIT THAT FEEDS MOTOR LOADS LIKE KITCHEN APPLIANCES, HVAC EQUIPMENT, 
WASHER/DRYER, OR GARAGE DOOR OPENERS. Sensor must be below and as far as possible away from lights. Sensor 
functions best when the direction of expected movement is across its detection pattern, not towards the sensor. Mount 
6–12 feet high for optimum range and detection.

MOUNTING

SETTINGS

STL200H/L and STL200HB/L come pre-wired and assembled on the 

RAB CU4 EZ Plate

, allowing for mounting on round, rectangular or 

octagonal surface or recessed boxes as shown in 

Fig. 1

.

Stealth’s infrared sensor “sees” small temperature changes caused 
by the motion of people or cars within its protection zone and turns 
on lights automatically. It welcomes visitors and may deter intruders.

How long do the lights stay on?

 Lights remain on as long as there 

is movement within the protection zone. Once the zone is vacated 
lights can be adjusted to remain on approximately 5 seconds up 
to 12 minutes. Since the lights are on only when needed and the 
sensor uses only one watt the Stealth is extremely energy effi  cient.

Can outdoor lights still be turned on with the light switch? 

Yes. 

Stealth can be controlled by a conventional indoor switch or circuit 
breaker. Lights can be turned on or off  manually at night only. 

Manual Override Mode:

 (to keep lights on) Flip the switch twice 

slowly (off -on-off -on) within 2–3 seconds.

To Resume Automatic Mode:

 Flip the switch once (off -on) within 

2 seconds. Sensor will reset to Automatic Mode.

STL200H/L

STL200HB/L

Bar 

Hook 

Screws

CU4 EZ

Plate

Universal

Mounting Bar

Gasket

Center 

Screw

Insert

close-up

plugs in

unused

holes

Finishing

Cap

O-Ring Gasket

Summary of Contents for STL200H/L

Page 1: ...R GARAGE DOOR OPENERS Sensor must be below and as far as possible away from lights Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 feet high for optimum range and detection MOUNTING SETTINGS STL200H L and STL200HB L come pre wired and assembled on the RAB CU4 EZ Plate allowing for mounting on round rectangular or octag...

Page 2: ...he lens For night only operation turn the knob all the way clockwise to to the moon symbol For 24 hour operation turn the knob all the way counterclockwise sun moon Adjust clockwise to have the sensor come on later at dusk counter clockwise to have it come on earlier Factory Setting Night Only The red LED above the lens shows the logic state of the sensor If the sensor is set for night only operat...

Page 3: ...ur STL200 kit to a surface mount weatherproof box you must use the metal plate with the attached gasket The gasket faces the Junction Box 2 Easy Wiring Tip Use the S shaped Hands Free Hanging Hook to hold the EZ Plate during wiring 3 Bring power leads and sensor kit leads through holes in all gaskets into junction box 4 Strip 1 2 of insulation from all leads 5 Attach ground wire s to junction box ...

Page 4: ... Lights Do Not Turn Off 1 Make sure that the sensor is not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 5 minutes then it will switch to Auto Mode with lights off and ready to detect movement 2 Make sure sensor is not aimed at or mounted over something that would move or change temperature such as waving branches water air conditioners...

Page 5: ...cated circuit free of motor loads such as HVAC equipment kitchen appliances or garage door openers 2 It is not recommended to wire sensors in parallel More than one sensor wired together makes them difficult to troubleshoot Disconnect multiple sensors and test separately 3 Keep all people completely out of the detection pattern to make sure the sensor is not detecting them 4 Make sure sensor is lo...

Page 6: ...higher ambient light levels turn the photocell control center knob toward the sun symbol 4 Was sensor wired hot If so circuitry may have been damaged Range Appears Limited 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Lights Turn Off Too Quickly 1 Check if sensor is being...

Page 7: ...tion Much Sooner PATHWAY 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move the sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Lights Turn On for Unknown Reasons 1 Lights may turn on occasionally during rain snow and windstorms because the sensor is detecting changes in tempera...

Reviews: