background image

INSTRUCTIONS

 

STL200H/L, STL200HB/L INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

SETTINGS 

(cont’d)

Fig. 3

Fig. 4

Fig. 2

HOW DOES THE LED DETECTION 
INDICATOR WORK?

LED Detection

Indicator

Masking the Lens 

 

100˚

Top View 30’

Side View 30’

10’

Detection Pattern

CHOOSING A LOCATION

Note:  

These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Will Stealth detect animals?

 Stealth may detect large animals. 

Having animals trigger the sensor can give property a “lived-in” 
look. However, you can limit animal detection by turning down the 
sensitivity knob and/or by using the plastic lens mask supplied on 
the lower part of the lens as shown in 

Fig 2

.

How are the Time, Sensitivity and Photocell adjusted? Fig 3

  

Time:

 Sets the time that lights will remain on after the detection 

zone is vacated from approximately 5 seconds to 12 minutes. 
Factory Setting: 5–8 minutes 

Sensitivity:

 Increases or decreases the responsiveness and range of 

the sensor (Adjusts from 30% to 100%) Factory Setting: 100% 

Photocell:

 Located behind the lens. For night only operation,  

turn the knob all the way clockwise to (to the moon symbol).  
For 24 hour operation turn the knob all the way counterclockwise 
(sun & moon). Adjust clockwise to have the sensor come on later at 
dusk, counter-clockwise to have it come on earlier. Factory Setting: 
Night Only.

The red LED above the lens shows the logic state of the sensor. If 
the sensor is set for night only operation, the LED will go on for 
daytime detections without turning on the lights 

(Fig 4)

. At night, 

the LED will be on all the time, except during detections (at which 
time the controlled lights will go on). At night, the LED serves as a 
deterrent indicating a security device in operation.

Choose a location from which the sensor can “see” all the paths of 
movement. The sensor may be wall or ceiling mounted.
As distance from the sensor increases, it will take more movement 
to be detected. For instance, at 10 feet, a half step will be enough, 
while at 40 feet several steps will be necessary.

How large an area does Stealth200 detect?

 The Stealth200 

provides a 200

°

 detection pattern. To reduce the angle of coverage 

on either or both sides, use the plastic blinders provided 

(Fig 2)

.  

The blinders can also be cut sideways and used to reduce low or 
high detection.
The sensor maybe swiveled in any direction to to cover the area 
desired. Always keep the sensor level to ensure full coverage.  
To reduce coverage, aim the sensor towards the ground.
Stealth STL200 comes with a standard “Double Look Down” Lens. 
This lens has one “Look Out” zone and two “Look Down” zones, for 
excellent detection both at long and close range.

Summary of Contents for STL200H/L

Page 1: ...R GARAGE DOOR OPENERS Sensor must be below and as far as possible away from lights Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 12 feet high for optimum range and detection MOUNTING SETTINGS STL200H L and STL200HB L come pre wired and assembled on the RAB CU4 EZ Plate allowing for mounting on round rectangular or octag...

Page 2: ...he lens For night only operation turn the knob all the way clockwise to to the moon symbol For 24 hour operation turn the knob all the way counterclockwise sun moon Adjust clockwise to have the sensor come on later at dusk counter clockwise to have it come on earlier Factory Setting Night Only The red LED above the lens shows the logic state of the sensor If the sensor is set for night only operat...

Page 3: ...ur STL200 kit to a surface mount weatherproof box you must use the metal plate with the attached gasket The gasket faces the Junction Box 2 Easy Wiring Tip Use the S shaped Hands Free Hanging Hook to hold the EZ Plate during wiring 3 Bring power leads and sensor kit leads through holes in all gaskets into junction box 4 Strip 1 2 of insulation from all leads 5 Attach ground wire s to junction box ...

Page 4: ... Lights Do Not Turn Off 1 Make sure that the sensor is not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 5 minutes then it will switch to Auto Mode with lights off and ready to detect movement 2 Make sure sensor is not aimed at or mounted over something that would move or change temperature such as waving branches water air conditioners...

Page 5: ...cated circuit free of motor loads such as HVAC equipment kitchen appliances or garage door openers 2 It is not recommended to wire sensors in parallel More than one sensor wired together makes them difficult to troubleshoot Disconnect multiple sensors and test separately 3 Keep all people completely out of the detection pattern to make sure the sensor is not detecting them 4 Make sure sensor is lo...

Page 6: ...higher ambient light levels turn the photocell control center knob toward the sun symbol 4 Was sensor wired hot If so circuitry may have been damaged Range Appears Limited 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Lights Turn Off Too Quickly 1 Check if sensor is being...

Page 7: ...tion Much Sooner PATHWAY 3 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move the sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Lights Turn On for Unknown Reasons 1 Lights may turn on occasionally during rain snow and windstorms because the sensor is detecting changes in tempera...