Firmware v5.x
Note
If you define the different resistor value for the internal ADC input, the firmware will choose the closest
resistor to the specified value
The measured analog value can be calculated into a corresponding temperature by the drive itself. Details
are described in
For details about using temperature sensors please
check our System integration guide
.
1.2.2.1.4.1 Specification for the single-ended temperature sensor
input
Symbol Min. typical Max. Description
Impact
V
0V
+5V
The input voltage between the
input and GND.
Any voltage out of this range causes
saturation to the min/max ADC value.
in
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01