1.2.1.3.2 Ambient air
Operation in ambient air temperature cooler than specified above is no appropriate measure to increase the
specifications of the device, neither in power nor in current. Operation in ambient air temperature hotter
than specified above is not allowed.
Note
If Circulo is mounted directly to a motor, it must be considered that motors can reach significantly
higher temperatures if continuously being operated at their max. continuous current. In such a case,
the full continuous torque spec of the motor cannot be used continuously. This must be considered
during design - in doubt, a motor model with higher max. continuous torque should be used to keep
the motor temperature lower, thus maintain the mounting temperature requirements.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
49/1031