Time from when the brake is commanded to engage, to when the controller is disabled. It is ignored in
manual mode.
Name
Index:Sub Type
Bit
Size
Min
Data
Max Data
Default
Data
Unit
Access
PDO
Mapping
DC bus
voltage
(deprecated)
0x2004:6
UINT
16
0
V
readonly
(default)
Deprecated. Refer to
0x6079 DC link circuit voltage
instead.
Name
Index:Sub Type
Bit
Size
Options
Unit
Access
PDO
Mapping
Brake status
0x2004:7
USINT
8
Not configured
0
Engaged
1
Disengaged
2
readwrite
Reports the status of the brake. Can also control the brake in automatic mode (Pin brake or Clutch brake)*
The options for controlling or reading this value are:
Not configured
(0) - No action will be taken for the brake
Engaged
(1) - The brake will prevent motion (Output voltage disabled in manual mode)
Disengaged
(2) - The brake will not prevent motion (Output voltage applied to 4th phase in manual
mode)
* In Manual Mode, output voltage is controlled by bit 0 of
Digital Output Object (0x60FE)
Name
Index:Sub Type
Bit
Size
Min
Data
Max Data
Default
Data
Unit
Access
PDO
Mapping
Minimum
displacement
(pin brake)
0x2004:8
UDINT 32
0
2147483647 0
readwrite
Minimum angle that the motor needs to turn in before it is certain that the brake pin is pulled out. The
units are in commutation sensor increments.
Name
Index:Sub Type
Bit
Size
Min
Data
Max Data
Default
Data
Unit
Access
PDO
Mapping
Maximum
torque (pin
brake)
0x2004:9
UINT
16
0
mNm readwrite
Maximum torque applied to the brake during the release process. The units are in mNm.
Name
Index:Sub Type
Bit
Size
Min
Data
Max Data
Default
Data
Unit
Access
PDO
Mapping
Output
voltage
0x2004:10 UINT
16
0
mV
readwrite Receive
PDO
(Outputs)
Voltage which is applied on the 4th phase when the Release strategy is set to manual mode (0) and
Physical output bit 0 as well as corresponding Bit mask in object
0x60FE
is set to 1.