3.1.9.1.89 0x605A Quick stop option code
Indicates what action is performed when the quick stop function is executed. The slow down ramp is the
deceleration value of the used mode of operations. The table below shows the value defenitions for the
function.
Value
Definition
0
Disable drive function
2
Slow down on quick stop ramp and transit into switch on disabled
6
Slow down on quick stop ramp and stay in quick stop active
Name
Index:Sub Type
Bit
Size
Options
Unit Access
PDO
Mapping
Quick stop option
code
0x605A:0
UINT
16
Disable Drive
Function
0
Slow down on
quick stop ramp
and transit into
switch on disabled
2
Slow down on
quick stop ramp
and stay in quick
stop active
6
readwrite
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
884/1031