This limit is updated in each execution loop of the torque control, and it limits the absolute value of reference
torque.
Note
By default the power of each Drive is internally limited to 110% of its maximum peak output power. As
a result, this object will only be effective if its value is less than 110% of Drive’s maximum peak output
power.
3.1.3.6.4 Parameters
Sets the limit in Watt
Shows the warning “MxPwrLmt” once the limit is reached
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
553/1031