1.2.4 Safety functions (STO-SBC)
SOMANET Circulo provides two drive integrated safety functions according to EN 61800-5-2:2017 as a pure
hardware solution
1. STO (Safe Torque Off) prevents the creation of torque in the motor and enables an uncontrolled stop in
accordance with stop category 0 of IEC 60204-1:2016.
2. SBC (Safe Brake Control) prevents electrical current to be supplied to the brake output and thus safely
closes the external brake.
Attention
The safety circuit safely inhibits currents to the motor and to a brake when STO-SBC command has
been given (e.g. from an emergency stop device).
When the command has been released (e.g. manually resetting the emergency stop device) the
currents are allowed to be carried to the motor and to the brake.
The safety system must be designed to meet the requirement “restarting the machinery after a
stoppage must be possible only by an intended actuation of a control device provided for the
purpose”.
Specifications of the safety functions
Examples for realising safety functions
Emergency stop
Stop category 1 emergency stop (Safe stop 1)
Prevention of unexpected start-up
Changelog of the safety-related documentation
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01