1.5.1.4.1 Safety specifications
1.5.1.4.1.1 System requirements
Required Firmware
v4.2.0 or higher
1.5.1.4.1.2 Technical specifications
Safety parameters
Safety Integration level (SIL) according to IEC 61508-
1:2010
3
Performance Level (PL) according to ISO 13849-
1:2015
e
Probability of dangerous failure per hour (PFH)
TBD
Probability of dangerous failure on demand
(PFDavg)
TBD
Hardware Fault Tolerance (HFT)
1
Reaction time
20 ms
Category (cat.)
3
Mean Time to Failure (MTTFd)
TBD
Diagnostic coverage (DCavg)
TBD
HW-type
Type A
Max. installation altitude
2000 m
Safe digital inputs (STO-SBC input)
Number of digital inputs
2 (dual-channel safety input for activating STO-SBC
function)
Digital input type according to IEC61131-2:2007
Type 1
Voltage range
0-30 VDC
Max. peak input voltage.
60 VDC
Input voltage, logic 1
15-30 V
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01
284/1031