21.2.3 LTS Troubleshooting
Table 21-4 LTS Troubleshooting
Issue
Possible Cause
Remedy
No lights turn on
QEC not receiving 12V power
• Measure voltage at the
PowerGen 12V posts
• Check fuse on jumper
cables
• Inspect wiring
No start, remains in
standby for over 30
minutes
Gas valve heater not
operating
• Check if valve and pump
are warm
• Check gas valve NTC is
seated correctly
• Check fuses and wiring
• Check 13V supply
Fault 2017
Pump heater not operating
• Check if pump is warm
• Check fuses and wiring
Very loud hammering
noise upon startup
Engine mount heater not
operating
• Disable PowerGen
• Check if all 4 engine
mounts are warm
• Check fuses and wiring
• Replace heater if needed
Warning 4017 or
power output
restricted
Fans are not spinning
Inspect fans and remove any
obstructions. Manually spin
blade to get it started.
Fault 2014
Air fuel mixture is too lean
• Refer to Fault 2014 in
Fault 3003, standby
Condensates forming or
propane frozen
Preheat gas lines and
regulators. Install GCU.
Fault 1008/2025
Blower stuck
Clear fault and re-enable.
Replace blower.
Summary of Contents for PowerGen 5650 Series
Page 1: ...7045 102089 000 June 1 2021 Installation Operation Manual FOR A QUALIFIED INSTALLER...
Page 8: ...iv...
Page 12: ...iv Figure 21 9 ATS Enclosure 179 Figure 21 10 Battery Connection Schematic 181...
Page 28: ...SYSTEM INTRODUCTION 16 Figure 3 6 P ID Diagram...
Page 69: ...QNERGY LYNX SOFTWARE 57 Figure 6 57 FPC FEB QEC Firmware Update...
Page 158: ...MAINTENANCE 146 Figure 17 2 Radiator and Over Flow Tank...
Page 194: ...POWERGEN OPTIONAL FEATURE SETS 182...